Skip to main content

eWeigh Self-Calibration

If your bars are not listed under Weigh Bar Type, or you are having trouble getting an accurate weight, use Self-Calibration

Georgia Foster avatar
Written by Georgia Foster
Updated over 2 weeks ago

For the first time setup with Self-Calibration, you will need to follow these setup preferences:

  • Speed or Accuracy = Accuracy

  • Weigh Bar/Load Cell Configuration = Select the relevant load bar left/right or both

  • Species Being Weighed = Sheep or Cattle

  • Weigh Bar Type = Self-Calibration


How to Self-Calibrate the Weight:

Step 1. Connect your eWeigh on the Equipment page as usual and tap 'Go Weigh'

Step 2. Select the preferences as recommended above, Accuracy, load bar configuration, species and Self Calibration under 'Which Bar Type' and then tap 'Go Weigh' again

Next, place a fixed weight onto the weighing platform. We recommend using a 50kg and a minimum of 25kg calibrated weight; however, any static item with a known weight, e.g. bag of feed or minerals, can be used

Step 3. Once the weight is in and is stable, the iLivestock application will ask you for the 'Correct Weight'

Once you enter the new weight, press 'OK'

The eWeigh will then calculate the weight again, and the known weight should display as you have entered it - in this case, 50kg.

Note: Once you have Self-Calibrated, the eWeigh will work with this calibrated weight. If you are not happy with the calibrated weight and want to calibrate again, please reset the eWeigh settings and then run the self-calibration process again.


How to Clear eWeigh Settings:

Step 1. On the Equipment page, make sure the eWeigh is successfully paired and under the eWeigh select Settings

Step 2. On the following screen, tap the Clear eWeigh Setup option

Step 3. Next, a confirmation pop-up will appear. Tap Confirm to Clear eWeigh Settings.

Your eWeigh settings will now be cleared when you press the Go Weigh button on the equipment page. You can then add your eWeigh settings and start the self-calibration process again.


IMPORTANT:

  • Make sure your load cells are correctly plugged into the eWeigh.

  • The stable weight displayed before you are prompted to enter the correct weight will look strange/out

  • Check that you and no one else is in contact with the crush/weighing area. No leaning or touching, or tying to any gates or posts, as this will seriously affect your calibration.

  • Anything that will shift the centre of gravity of the crush also has an impact on the self-calibrated reading (e.g swing door). Make sure once the weight is in the crush and that all doors are closed and the feet of the bars are on even, clear ground


Online: Use the chat icon in Admin on the app or bottom right on the web dashboard

Call: 01383 324358